The north zone design live load equates to 40 pounds per square foot the middle zone equates to 30 pounds per square foot and the south zone equates to 20 pounds per square foot.
Roof snow load for indiana.
Chapter 16 structural design.
2018 international building code.
Use our roof snow load calculator to determine your design roof snow loads.
Purpose of this web site.
2018 international building code.
The purpose of this web site is to provide ground snow load analysis information and data gathered from all 50 states.
There are of course special cases like deep drift loads on large flat roofs.
If the snow weighs 10 pounds per cubic foot and there are 1 5 feet on the roof each square foot of the roof is getting 15 pounds of pressure.
If you need to gather ground snow load data programmatically please consider our api service.
For additional questions or concerns about specific ground snow loads please call us at 1 425 741 5555.
The publication is 20 and may be purchased from msu civil engineering at 406 994 2111.
Each state has a listing of building code and applicable guidelines for snow loads as well as details about where the snow load information may be found or purchased.
In other words on a steep roof less material would be stacked in a concentrated area at one time to avoid having it slide off.
P s c s p f where.
And sliding loads where snow slipping off a higher roof inundates a lower one that should be looked at carefully by a structural designer.
Please review our state snow loads page to investigate state specific snow load requirements.
The building codes don t attempt to account for all possible snow load scenarios.
If your roof is 1 000 square feet the total snow load is 15 000 pounds of snow.
If you live in the us our snow load calculator compares the total weight on your roof with the permissible load calculated according to the standards issued by the american society of civil engineers regarding the minimum design loads for buildings and other structures asce7 16.
In my region on cape cod we have a ground snow load design of 25 psf which is a greater design load than the live load 12 psf to 20 psf over an entire roof system.
Chapter 15 roof assemblies and rooftop structures.
Roof slope factor c s the roof slope factor is dependent on various roof properties including temperature shape and material.
Also extremely relevant to roofs with sections on rain loads snow loads and wind loads.
On the upcodes website.
On the upcodes website.
To figure out the load on your roof take the depth of snow in feet and multiply it by the weight of a cubic foot of snow.
The north zone middle zone and the south zone are identified on the roof load zone map above.
This downward imposed load on the home is also known as the snow load.